MENU
HOME > Blog > Oversea sales blog > Compact ultrasonic atomizer unit HM series.

Compact ultrasonic atomizer unit HM series.

 

Ultrasonic atomizer unit HM series.

Ultrasonic atomizer unit frequency is 2.4MHz, which is higher than Ultrasonic humidifier unit.
It atomizes super fine particles(under 3μm).

HM2412 and HM2412C which we used to selling had discontinue to manufacture.
For people who will design newly, please consider to get HMC-2400(atomize right above, attached horn), or HMC-2401(atomize diagonally).
※We already finished accepting final order of HM-2412 and HM-2412C in 2018/11/30.

What’s different from old models?

The most big different point is “shape of oscillator”.
On picture below, left side oscillator is old model, and right side one is HMC series.
As the volume of oscillator get smaller in 1/3, it doesn’t need big space for setting.
※Measure of Substrate and heat sink L 38mm×W 30mm×H 36mm±3mm
※Weight 17g(Measured in our company)

超音波霧化ユニット

The shape of transducer has also changed.

The length of screw setting is same, but the material and packing has changed to same one as installed in JM-200. (Picture below: Left side- Old models   Right side- HM-2400)

振動子形状比較

Also, about the HMC-2400, it accessories resin horn to increase a volume of atomization.
If you don’t equip a horn, it atomizes 150ml in hour. If you equip a horn, it atomizes 360ml in hour.(※Because proper water level is different from old model, pay attention when you replace from old model)

Ultrasonic atomizer unit HM-2401 transducer is angled 10°same as old models, to make stable a mist avoid from water fallen directly. For designing, do not place something on direction that water emits.

As the substrate sized down, it could tighten and set substrate with transducer.(Picture below: HMC series)
HMC2400一体取付

Ultrasonic atomizer unit has been used for various purposes, atomizing solution.
・Atomizing something solution. It mostly used at experiment in university.
 We don’t recommend for atomizing toxic substance, but there are cases of experiment that
 atomizing with double vessel.
Check how to atomize within double vessel. (※This is immersion type ultrasonic atomizer)

・Make available to see laser, environment test in dense fog and high humidity place, by using mist.
・Equip on machine, for countermeasure of static electricity, and atomizing HClO or slightly acidic electrolytic water.
・Producing nanoparticle

HMC-2400 Specification of “Overhead ・ Equipped Horn”

(Model) HMC-2400
(Oscillation frequency) 2.4MHz
(Power consumption) 14VA
(Proper water level)
・Normal use: Transducer – water surface 36mm±5mm
・Horn equipped use: Transducer – water surface 43mm±5mm
(Ambient temperature):5℃~35℃(Not ensuring specification)
(Capability of atomization):※Test condition※ Measured in water temperature 25℃
・Normal use: Approx. 150ml/h
・Horn equipped use: Approx. 360ml/h
External dimensions: Substrate ・ Heat sink: W 38mm×D30mm×H36±3mm
Circuit cooling system: Forced air cooling (Cooling fan, air capacity upper 14CFM)
Product Set: Oscillation circuit board, HMC-2400 transducer ASSY, Bundle power cord, Bundle float switch cord, Horn

HMC-2401 Specification of “Oblique transducer ・ Replacement of old models”

(Model) HMC-2401
(Oscillation frequency) 2.4MHz
(Consumption power) 15VA
(Proper water level)
・Normal use: Transducer – water surface 32.5mm±5mm
Ambient temperature: 5℃~35℃(Not ensuring specification)
Capability of atomization:※Test condition※ Measured in water temperature 25℃
・約190ml/h
External dimensions: Substrate ・ Heat sink: W38mm×D30mm×H36±3mm
Circuit cooling system: Forced air cooling (Cooling fan, air capacity upper 14CFM)
Product set: Oscillation circuit board, HMC-2401 transducer ASSY, Bundle power cord, Bundle float switch cord

Water tank set ・ difference of specification, and other points

霧化ユニット取り付け他
霧化ユニット取り付け他

※超音波霧化ユニットとは※
 超音波霧化ユニットとは、液体に高周波の超音波を与えることで、水の分子が加速し水柱が立ち上がります。水柱の先端付近で耐え切れなくなった液体が微粒化し霧状になります。この現象を利用して、液体を微粒化する装置に組み込むことを想定した超音波振動子と振動子を駆動する発振器をセットした商品です。
 元々、自社で販売をする超音波霧化装置用として開発。特注装置を依頼される企業や大学などの研究部門から、霧を作り出すユニットだけを販売をしてほしいと要望があり、H10年(1998年)8月1日に新聞発表、発売を開始しました。
1個から購入し、試作・実験が出来るということで、長年、各方面でご利用頂いています。

□供給体制
・自社の製造能力に限りがあり、特に次亜塩素酸水対応素子に関しては大量ロットを供給出来ません。現在、数千枚/月を越えるオーダーはお断りしております。
・条件があえば、超音波霧化器、超音波加湿器、超音波噴霧器など液剤を霧にする事を目的とした競合製品を製造している企業様にも供給をしております。
 次亜塩素酸水、微酸性電解水などで超音波素子が破損し困っている企業様は、ご相談下さい。

□コスト
・国内で次亜塩素酸水・微酸性電解水対応の超音波振動子がほぼ無いため、多くの企業様からお引合い頂きますが、コスト的には一般的な加湿用振動子よりも、数倍~数十倍高いお見積になります。
 

Japanese purchasing page

超音波霧化ユニット(2.4MHz) HMC-2400
Ultrasonic atomizer unit (2.4MHz) HMC-2400
Product code : hmc2400
 
超音波霧化ユニット(2.4MHz) 振動子assy HMC-2400TDassy
Ultrasonic atomizer unit (2.4MHz) transducer ASSY HMC-2400TDassy
Product code : hmc2400tdassy
 
 
超音波霧化ユニット HMC-2401
Ultrasonic atomizer unit HMC-2401
Product code : hmc2401
 
超音波霧化ユニット(2.4MHz) 振動子assy 斜めHMC-2401TDassy
Ultrasonic atomizer unit (2.4MHz) transducer ASSY Oblique HMC-2401TDassy
Product code : hmc2401tdassy
 
アタッチメント(HM2412取付穴にHMCを取付たい)
Attachment part (Set HMC on the HM2412)
商品コード : hmc2400henkan
 

※ジアミストは、当社登録商標です。
 当社商標ジアミスト裁判に関して

※2020/10/15 仕様表記一部変更
※質問に対する回答を下記に追加2020/10/19
 質問:振動子をアンプで直接駆動したい。
    振動子に印加する電圧と流れる電流,消費電力を教えてください。
 回答:当社で販売しているユニットは、セット購入を前提としています。
    また、振動子への印加電圧及び電流、消費電力に関しましては情報を公開して
    おりません。
    購入後、測定するか、他社製の超音波加湿用振動子をご検討下さい。

※質問に対する回答を下記に追加2020/10/19
 質問:霧化発振基板のR3が焼損するのは何故ですか?またヒューズで対策可能ですか?
 回答:振動子未接続(空焚きなどの異常発熱で振動子の半田が取れた場合を想定)で通電する
    と異常発振(500KHz~600KHz)し、3分以内でR3から発煙することを確認しています。
    調整電流値550mAに対して異常発振時の電流値は約200mAで電流値としては下がって
    います。そのためヒューズ等で保護することは困難と思われます。
    動作確認で超音波振動子を接続しない状態で、通電しないようにして下さい。

※質問に対する回答を下記に追加2020/10/20
 質問:高周波利用設備申請が不要な台数は何台ですか?
 回答:ぎりぎり5台までです。
    高周波利用設備申請などに関するフォローは当社では行いません。

※質問に対する回答を下記に追加2020/11/18
 質問:ファンが無い場合はどうなりますか?
 回答:放熱板の温度が10分後には90℃を超えますので、FETが破損する可能性があります。

[mwform_formkey key="2639"]